電纜橋架布線有什么技巧?

電纜橋架如何布線呢?下面是山東電纜橋架廠家給我們總結的橋架布線技巧,希望對大家有所幫助!
How to wiring the cable bridge? The following is the bridge wiring skills summarized by Shandong cable bridge manufacturers. I hope it will be helpful to you all! 
一、電纜橋架水平安裝時,宜按荷載曲線選取更佳跨距進行支撐,跨距一般為1.5~3m。垂直敷設時,其固定點間距不宜大于2m。
1. When the cable bridge is installed horizontally, the optimum span should be selected according to the load curve, and the span is generally 1.5-3 M. When laying vertically, the distance between fixed points should not be more than 2m.
二、幾組電纜橋架在同一高度平行安裝時,各相鄰電纜橋架間應考慮維護、檢修距離。
2. When several groups of cable bridges are installed in parallel at the same height, the distance between adjacent cable bridges should be considered for maintenance and repair.
三、在電纜橋架布線時,其電纜不應有黃麻或其他易延燃材料外護層。
3. When cables are cabled indoors, jute or other flammable materials shall not be used as outer protective layer for cables.
四、在有腐蝕或特別潮濕的場所采用電纜橋架布線時,應根據腐蝕介質的不同采取相應的防護措施,并宜選用塑料護套電纜。
4. When cables are used in corrosive or especially humid places, corresponding protective measures should be taken according to different corrosive media, and plastic sheathed cables should be selected.
山東電纜橋架
五、在電纜橋架上可以無間距敷設電纜,電纜在橋架內橫斷面的填充率:電力電纜不應大于40%;控制電纜不應大于50%。
5. Cables can be laid on the cable bridge without spacing. The filling rate of the cross section of the cable in the bridge frame should not be greater than 40% for power cables and 50% for control cables.
六、電纜橋架不宜安裝在腐蝕性氣體管道和熱力管道的上方及腐蝕性液體管道的下方,否則應采取防腐、隔熱措施。
6. Cable bridge should not be installed above corrosive gas pipeline and thermal pipeline and below corrosive liquid pipeline, otherwise anti-corrosion and heat insulation measures should be taken.
七、電纜橋架(托盤)水平安裝時的距地高度一般不宜低于2.50m,垂直安裝時距地1.80m以下部分應加金屬蓋板保護,但敷設在電氣專用房間(如配電室,電氣豎井、技術層等)內時除外。
7. The height of cable tray should not be less than 2.50M when it is installed horizontally, and the metal cover should be used to protect the part below 1.80m when it is installed vertically, except when it is laid in the special electrical room (such as distribution room, electric shaft, technical layer, etc.).