濟(jì)南電纜橋架近年來的發(fā)展比較迅速,它的使用能夠用于保護(hù)電纜的使用,使其使用效果比較美觀、配置相對比較靈活,可以保證良好的使用效果,因其使用場合不同,電纜橋架存在有多種類型,其中就包括不銹鋼電纜電纜橋架,它在安裝時需要注意一些具體的步驟:
Jinan cable trays have developed rapidly in recent years, and their use can be used to protect cables, making them more aesthetically pleasing and flexible in configuration, ensuring good usage. Due to different usage scenarios, there are various types of cable trays, including stainless steel cable trays. It is necessary to pay attention to some specific steps during installation:
(1)在房間內(nèi)選擇電纜不銹鋼電纜電纜橋架布線時,該電纜不需要黃麻或其他阻燃材料的外皮。
(1) When selecting a stainless steel cable tray for wiring in a room, the cable does not require a sheath of jute or other flame retardant materials.
(2)在有侵蝕或非常潮濕的場所選擇電纜不銹鋼電纜電纜橋架布線時,需要根據(jù)侵蝕物質(zhì)的不同采取有效的防護(hù)措施,可以采用塑料電纜。
(2) When selecting stainless steel cable trays for wiring in corrosive or very humid areas, effective protective measures need to be taken based on the different corrosive substances, and plastic cables can be used.
(3)電纜不銹鋼電纜架(托盤)水平安裝時的地面長寬比一般小于2.50米,垂直安裝時離地面1.80m以下的部分需要加入金屬材料用蓋板進(jìn)行維護(hù),但電氣設(shè)備專用型的房間(例如高
(3) When installing stainless steel cable racks (trays) horizontally, the ground aspect ratio is generally less than 2.50 meters. When installing vertically, metal materials need to be added to the parts below 1.80 meters above the ground for maintenance with cover plates. However, for electrical equipment specific rooms (such as high
(4)濟(jì)南電纜橋架中不銹鋼電纜電纜橋架水平安裝時,根據(jù)載荷曲線圖選擇跨度展開支撐點(diǎn)。 跨度一般為1.5~3M。 垂直鋪設(shè)時,其支撐點(diǎn)間隔超過1m是不合適的。
(4) When installing stainless steel cable trays horizontally in Jinan cable trays, select span expansion support points based on the load curve diagram. The span is generally 1.5-3M. When laying vertically, it is not appropriate to have support points spaced more than 1m apart.
(5)兩組電纜不銹鋼電纜電纜橋架安裝在同一長寬比平行面上時,各相鄰電纜不銹鋼電纜電纜橋架之間請考慮維護(hù)、維護(hù)間距。
(5) When two sets of stainless steel cable trays are installed on the same aspect ratio parallel surface, please consider maintenance and spacing between adjacent stainless steel cable trays.
(6)電纜線不銹鋼電纜架上可以無間隔鋪設(shè)電纜線,電纜線在不銹鋼電纜架內(nèi)橫截面的填充率:電線電纜不得超過40%。 變頻器電纜請控制在50%以下。
(6) Cable can be laid on stainless steel cable racks without gaps, and the filling rate of the cross-section of the cable in the stainless steel cable rack shall not exceed 40% for wires and cables. Please control the frequency converter cable below 50%.
(7)不同的動作電壓、不同的主要用途的電纜不適合鋪設(shè)在同一層的不銹鋼電纜架上。 標(biāo)準(zhǔn)規(guī)定時,安裝在同一層的不銹鋼電纜電纜橋架上時,用擋板隔開。
(7) Cables with different operating voltages and main purposes are not suitable for laying on stainless steel cable racks on the same layer. When installed on the same layer of stainless steel cable trays, baffles should be used to separate them according to standard regulations.